Pinlocity
All patterns

PBAChallenge

2023 PBA Jr. Tackett

PR4.2What's this?

Designed for: REVERSE DROP BRUSH

Distance
44 ft
Volume
26.10 mL
Ratio
6.19:1
Drop brush
36 ft
Forward
15.85 mL
Reverse
10.25 mL
Tanks
—
Pump
—
0260520780104013001L: 0 µL forward1L: 0 µL reverse12L: 150 µL forward2L: 50 µL reverse3L: 150 µL forward3L: 50 µL reverse34L: 150 µL forward4L: 50 µL reverse5L: 150 µL forward5L: 50 µL reverse56L: 150 µL forward6L: 50 µL reverse7L: 200 µL forward7L: 50 µL reverse78L: 200 µL forward8L: 100 µL reverse9L: 250 µL forward9L: 100 µL reverse910L: 300 µL forward10L: 200 µL reverse11L: 450 µL forward11L: 200 µL reverse1112L: 450 µL forward12L: 350 µL reverse13L: 600 µL forward13L: 350 µL reverse1314L: 600 µL forward14L: 450 µL reverse15L: 750 µL forward15L: 550 µL reverse1516L: 750 µL forward16L: 550 µL reverse17L: 750 µL forward17L: 550 µL reverse1718L: 750 µL forward18L: 550 µL reverse19L: 750 µL forward19L: 550 µL reverse1920L: 750 µL forward20L: 550 µL reverse19R: 750 µL forward19R: 550 µL reverse1918R: 750 µL forward18R: 550 µL reverse17R: 750 µL forward17R: 550 µL reverse1716R: 750 µL forward16R: 550 µL reverse15R: 750 µL forward15R: 550 µL reverse1514R: 750 µL forward14R: 550 µL reverse13R: 600 µL forward13R: 450 µL reverse1312R: 450 µL forward12R: 350 µL reverse11R: 300 µL forward11R: 200 µL reverse1110R: 300 µL forward10R: 100 µL reverse9R: 250 µL forward9R: 100 µL reverse98R: 200 µL forward8R: 100 µL reverse7R: 200 µL forward7R: 50 µL reverse76R: 150 µL forward6R: 50 µL reverse5R: 150 µL forward5R: 50 µL reverse54R: 150 µL forward4R: 50 µL reverse3R: 150 µL forward3R: 50 µL reverse32R: 150 µL forward2R: 50 µL reverse1R: 0 µL forward1R: 0 µL reverse1LEFTRIGHTforwardreverse

Forward loads

#StartStopLoadsMicsSpeedBuffTankDistanceT. oil
12L2R350103A -0 → 35,550
27L7R150143A -3 → 51,350
39L9R150143A -5 → 71,150
410L10R150183A -7 → 91,050
511L12R350143A -9 → 152,700
613L13R350183A -15 → 232,250
715L14R350183A -23 → 301,800
82L2R050183A -30 → 350
92L2R050223A -35 → 390
102L2R050303A -39 → 440
Total15,850 µL

Reverse loads

#StartStopLoadsMicsSpeedBuffTankDistanceT. oil
12L2R050223A -36 → 350
215L14R250183A -35 → 301,200
314L13R250183A -30 → 251,400
412L12R350183A -25 → 172,550
510L11R250143A -17 → 132,000
68L8R150143A -13 → 111,250
72L2R150143A -11 → 101,850
82L2R050103A -10 → 00
Total10,250 µL

Pinlocity Rating (PR)

How hard this pattern plays, 1 (a walled house shot) to 10 (long, flat, and heavy). Moderate. Computed from the sheet numbers and the load tables; no opinions involved.

PR4.2
  • Ratio 45%3.3Flatter patterns score higher. 10:1 walls score 1, dead flat scores 10.
  • Distance 25%6.439 to 41 ft is the playable band; longer and shorter both climb.
  • Outside oil 20%3.3Oil on boards 3 to 7 takes away the miss room, measured from the load tables.
  • Volume 10%4.920 to 26 mL is typical; heavier or lighter both add difficulty.

What the community throws here

Collecting. Community insights unlock once 25 different bowlers have shared games on this pattern.

0 of 25 bowlers so far. Log games on this pattern and turn on Contribute my games anonymously under a bowler's Privacy tab to help. Nothing identifying is ever stored in the totals.

Notes

Kegel Pattern Library: Pba Patterns / PBA Jr. Patterns.

Sheet dated 2024-01-01. Pattern data from the Kegel Pattern Library, reproduced with credit to Kegel and PBA.